Design and construction of a biominilab for biomedical research (part II) = Conception et construction d'un biominilab pour la recherche biomédicale (seconde partie)
| dc.contributor.affiliation | Laboratorio de Bioingenería, División de Investigaciones en Neurociencias, Instituto Mexicano de Psiquiatría | es_ES |
| dc.creator | Zapata, A. | |
| dc.creator | Rivas, L. | |
| dc.creator | Gaona, A. | |
| dc.creator | Chávez, M. | |
| dc.creator | Meza, A. | |
| dc.creator | Aguillón, M. | |
| dc.date.accessioned | 2017-06-29T04:19:34Z | |
| dc.date.accessioned | 2026-03-27T14:35:18Z | |
| dc.date.available | 2017-06-29T04:19:34Z | |
| dc.date.issued | 1996 | es_ES |
| dc.date.published | 1996 | es_ES |
| dc.description.abstract | This technical research describes the design and construction of a modular electronic system for bioelectrical signal recording using a magnetic record and a digital interface to turn a normal oscilloscope into a memory one. We also present a circuit breaker for recording and stimulating with the same electrode | es_ES |
| dc.description.abstractotrodioma | Dans cet article, on décrit la conception et la construction d'un système électronique modulaire pour l'enregistrement des signaux bioélectriques, l'étude du voltage clamp et l'équipement pour faire des lésions dans le tissu nerveux au moyen d'émission radiofréquence. Dans la deuxième partie de l'article nous décrivons une unité pour produire de l'épilepsie expérimentale; le système donne une signal qui permet de visualiser sur un oscilloscope à mémoire l'activité de la même façon qu'il permet l'enregistrement sur bande magnétique. | es_ES |
| dc.description.month | Jun | es_ES |
| dc.identifier | 228 | es_ES |
| dc.identifier.citation | Juan Carlos Bautista Ramírez | es_ES |
| dc.identifier.issn | 0243-7228 | es_ES |
| dc.identifier.numero | 3 | es_ES |
| dc.identifier.organizacion | Instituto Mexicano de Psiquiatría | es_ES |
| dc.identifier.paginacion | 257-264 | es_ES |
| dc.identifier.place | Francia | es_ES |
| dc.identifier.uri | https://repositorio.inprf.gob.mx/handle/123456789/4922 | |
| dc.identifier.volumen | 17 | es_ES |
| dc.language.iso | eng | es_ES |
| dc.relation | 17 (3) 257-264 p. | es_ES |
| dc.relation | versión del editor | es_ES |
| dc.relation.jnabreviado | INNOV TECHN BIOL MED | es_ES |
| dc.relation.journal | Innovation et Technologie en Biologie et Médecine : ITBM | es_ES |
| dc.rights | acceso cerrado | es_ES |
| dc.subject.ko | Magnetic tape | es_ES |
| dc.subject.ko | Memory oscilloscope | es_ES |
| dc.subject.ko | Epilepsy | es_ES |
| dc.subject.ko | Experimental disease | es_ES |
| dc.subject.ko | Kindling | es_ES |
| dc.subject.ko | Instrumentation | es_ES |
| dc.subject.ko | Electric device | es_ES |
| dc.subject.ko | Biomedical engineering | es_ES |
| dc.subject.ko | Nervous system diseases | es_ES |
| dc.subject.ko | Central nervous system disease | es_ES |
| dc.subject.ko | Cerebral disorder | es_ES |
| dc.subject.kw | Cinta magnética | es_ES |
| dc.subject.kw | Osciloscopio memoria | es_ES |
| dc.subject.kw | Epilepsia | es_ES |
| dc.subject.kw | Patología experimental | es_ES |
| dc.subject.kw | Instrumentación | es_ES |
| dc.subject.kw | Aparato eléctrico | es_ES |
| dc.subject.kw | Ingeniería biomédica | es_ES |
| dc.subject.kw | Sistema nervioso patología | es_ES |
| dc.subject.kw | Sistema nervioso central patología | es_ES |
| dc.subject.kw | Encéfalo patología | es_ES |
| dc.title | Design and construction of a biominilab for biomedical research (part II) = Conception et construction d'un biominilab pour la recherche biomédicale (seconde partie) | es_ES |